Type K Thermocouple [Full Guide] - Peak Sensors (2024)

What Is A Type K Thermocouple?

K Type Thermocouple Material

Type K Thermocouple is a Base metal thermocouple made from conductors containing Nickel – Chromium, and Nickel – Aluminium alloys and is suited for measuring temperatures up to +1200°C. We are K-type thermocouple manufacturers and can produce K-type thermocouple sensors based on your specifications or as replacements for existing sensors. We have manufactured thermocouples for over 25 years and are solely focused on designing and manufacturing temperature sensors. Please call or email us to discuss your requirements.

Need some help?

If you are unsure exactly what you need, get in touch and we can help identify your requirements.

Contact Us

How Do Type K Thermocouples Work?

Type K thermocouples operate based on the Seebeck effect, which generates a voltage when there is a temperature difference between the two junctions of dissimilar metals. This voltage is proportional to the temperature difference and can be measured to determine the temperature at the sensing junction accurately. The relationship between temperature and voltage is well-characterised and can be represented by specific calibration tables or equations.

K type thermocouples can come in a variety of designs suited to different applications. View the details of each type of design we offer for the type K thermocouples range.

  • Mineral Insulated Type K – Metal sheath insulated with magnesium oxide powder also called MIMS.
  • Cable/Wire Type K – Flexible sensors in PVC, PTFE or Glass Fibre. Many cold and hot-end designs.
  • Type K with Ceramic Sheaths – High-temperature design with ceramic protection sheath
  • Type K with Metal Sheaths – High temperature design with metal protection sheath
  • Type K Inserts – Rigid metal tubes commonly used in pocket, thermowell or head assemblies.
  • Type K Elements – Basic elements for further assembly into sheaths or equipment.

K Type Thermocouple Specifications

K type thermocouple sensors are by far the most common thermocouple type in use. It is quite an inexpensive sensor and we can manufacture many different designs of this thermocouple type. Its range is common for many industrial processes and is the main base metal thermocouple before switching to a rare metal thermocouple. The high nickel content of Type K means it is a very stable sensor. Thermocouple type K is unsuitable for reducing atmospheres unless it is protected by a sheath. It’s sensitivity is around 41 µV/°C.

Type K Thermocouple Temperature Range

Continuous:

0 to +1100 °C

Short Term:

-180 to +1300 °C

Type K Thermocouples Material

Chromel (90%Ni, 10%Cr)

Alumel (95%NI, 2%Mg, 2%Al, 1%Si)

Type K Thermocouple Tolerance Details

Tolerance Class 1

-40 to +375 ± 1.5 °C

375 to 1000 ± 0.004*[t]°C

Tolerance Class 2

-40 to +333 ± 2.5 °C

333 to 1200 ± 0.0075*[t]°C

Type K Thermocouple Colour Codes

IEC Colour Code

Type K Thermocouple [Full Guide] - Peak Sensors (1)

BS Colour Code

Type K Thermocouple [Full Guide] - Peak Sensors (2)

ANSI Colour Code

Type K Thermocouple [Full Guide] - Peak Sensors (3)

How To Test A Type K Thermocouple?

Testing a Type K thermocouple involves verifying its output voltage or temperature readings against a known reference source or calibrated instrument. This can be done using specialised thermocouple simulators, temperature baths, or other temperature measurement devices. Additionally, visual inspection for physical damage or signs of wear can also indicate the need for replacement or recalibration.

How To Calibrate A Type K Thermocouple?

Calibrating a Type K thermocouple involves comparing its output against known temperature standards over a range of temperatures. This process ensures that the thermocouple provides accurate temperature measurements within the specified tolerance limits. Calibration can be performed using certified temperature references and calibrated instruments following established procedures and standards.

How To Check A Type K Thermocouple With A Multimeter?

To check a Type K thermocouple with a multimeter, you can follow these steps:

  1. Set the multimeter to measure voltage (mV).
  2. Disconnect the Type K thermocouple from any circuitry.
  3. Connect the multimeter leads to the two ends of the Type K thermocouple.
  4. Read the voltage displayed on the multimeter.
  5. Compare the measured voltage with the expected voltage at a known temperature using Type K thermocouple reference tables or conversion formulas.

Which Wire Is Positive On A Type K Thermocouple?

In a Type K thermocouple, the positive wire is typically made of chromel (Nickel-Chromium), while the negative wire is made of alumel (Nickel-Aluminum).

Contact us

We’ve made Type K Thermocouples for over 25 years and today we are considered the best choice for custom built temperature sensors in the UK. We continue to apply our expertise and invest in the latest technology to provide our customers with the highest quality temperature sensors available.

Contact us with your requirements if you have an existing sensor design or are unsure what you need we’ll be able to find you get the right sensor for your process.

Submit an Enquiry

"*" indicates required fields

Type K Thermocouple [Full Guide] - Peak Sensors (2024)

References

Top Articles
Latest Posts
Article information

Author: Jeremiah Abshire

Last Updated:

Views: 5506

Rating: 4.3 / 5 (74 voted)

Reviews: 81% of readers found this page helpful

Author information

Name: Jeremiah Abshire

Birthday: 1993-09-14

Address: Apt. 425 92748 Jannie Centers, Port Nikitaville, VT 82110

Phone: +8096210939894

Job: Lead Healthcare Manager

Hobby: Watching movies, Watching movies, Knapping, LARPing, Coffee roasting, Lacemaking, Gaming

Introduction: My name is Jeremiah Abshire, I am a outstanding, kind, clever, hilarious, curious, hilarious, outstanding person who loves writing and wants to share my knowledge and understanding with you.